Runlist function

Executes IMSDBU functions listed in a Runlist command file.

The Runlist function executes IMSDBU functions listed in a Runlist command file. This file can be created manually with a text editor or generated by Makelist.

Syntax

mfims imsdbu RUN {database-name|filename}
     [[NO]CLS] 
     [ECHO(keyword,msglvl,stoplvl
     [[NO]INI(filespec)]
     [[NO]LIST(filespec)]
     [LISTOPEN(disp)]
     [[NO]LOG(filespec)]
     [PROGRESS(no-of-segments)]

Parameters

database-name
The name of a database on which the function operates.
filename
The name of a file containing a list of databases on which the function operates.
CLS
Clears the screen before starting the utility. NOCLS prevents the initial clear screen and can be helpful when you are running a series of utilities in a command file.
Default: NOCLS
ECHO
Controls the display of and interaction with the messages displayed by IMSDBU.
Default: ECHO(MSGS,4,8)
Sub-parameters
keyword The category of information displayed. One of the following:
ALL
Always displays processing messages, input source or detail information and the ending message. Warning and error messages are displayed and stop for user input if the message level is equal to or greater than the msglvl and stoplvl values.
MSGS
Always displays processing messages and the ending message. No source or detail information is displayed. Warning and error messages are displayed and stop for user input if the message level is equal to or greater than the msglvl and stoplvl values.
ERREND
Always displays the utility ending message. Warning and error messages are displayed and stop for user input if the message level is equal to or greater than the msglvl and stoplvl values.
ENDMSG
Displays ending message only if the utility ending return code is equal to or greater than msglvl. A "Press any key to continue" message is displayed and stops for input if the utility ending return code is equal to or greater than the stoplvl. Enter a msglvl and/or stoplvl value of zero to display and/or stop on every ending message.
COND
Both the warning/error and ending messages are conditional on the msglvl and stoplvl values. Warning and error messages are displayed and stop for user input if the message level is equal to or greater than the msglvl and stoplvl values. The ending message is displayed if the ending return code is equal to or greater than msglvl. You see the message "Press any key to continue" which requires input if the utility ending return code is equal to or greater than the stoplvl.
ERRORS
You see warning and error messages which require input if the message level is equal to or greater than the msglvl and stoplvl. You do not see the ending message.
msglvl A value from 4 through 20 to indicate the severity of messages to display.1
stoplvl A value from 4 through 20 to indicate the severity of messages to stop for user input. 1
1 Can take the following values:
Value Category Example Cause
4 General warning message A minor coding error in DBD source which DBDGEN can make an assumption about and continue.
6 IMS specific warning message A warning that a keyword or statement is not supported and is ignored - processing can continue.
8 General severe error An incorrect coding in DBD source which cannot be compensated for, such as 'no DBD statement'.
10 IMS Option specific severe error An unsupported feature was defined which cannot be compensated for, such as 'Exceeded some maximum'.
12 Severe error - possible temporary condition A temporary I/O error such as a 'file locked' or 'database locked' status.
16 Severe error- permanent - likely installation problem A permanent I/O error, such as an invalid data set name or member name, was input to a utility or an environment variable is not set correctly.
20 Severe error - permanent An unrecoverable I/O error or some other unexpected error.
INI
Specifies the default directives file.
Default: None
Sub-parameter
filespec The name and location of the .INI file containing directives that override the IMSDBU programmed defaults.
Syntax Rules
  1. filespec can include a drive and/or directory if required. If you do not specify a drive or directory, IMSDBU looks for the named .INI file in the current directory.
  2. Directives listed in the .INI file override the IMSDBU programmed defaults.
  3. Directives entered on the command line or interactive screen override directives in the .INI file.
  4. Specifying NOINI prevents any .INI file from overriding the programmed defaults.
  5. If you specify an .INI file that does not exist, the programmed default directives are used as if NOINI were specified.
General Rules
  1. An .INI file is an ASCII text file containing a heading, [IMSDBU] on line 1, starting in column 1, followed by a list of mfims imsdbu directives; one directive per line. A line is terminated by a return or an end-of-file. Comment lines are indicated by an asterisk (*) or semi-colon (;) in column 1. For example:
    [IMSDBU]
    PROGRESS(1000)
    ;use local log
    LOG(C:\MYDIR\MYDB.LOG)
LIST
Controls the location and name of the detail listing file, which includes items such as source listings, completion status,